Clocking CNG Compressor for Gas Flow
To clock a gas compressor you will need to identify the following: That the only load on the gas meter is the compressor you are clocking. What the gas pressure is at the meter while you are clocking. What the smallest rotary dial on the meter measures in one revolution. Next, record how long it takes for a given amount of gas to go through the meter and what pressure the meter was at when you clocked it. Now the fun part; use the following formulas: Correction Factor =...